⚠️ Risk Assessment

Download link: #007 - Soldering Area - 261029.pdf

#

Identify Hazards

Risk

Who may be harmed

Severity

Control Measures

Likelihood

Risk Rating

1

Electricity

Users risk burns or shock from equipment use

User

High

All electrical equipment should be checked for electrical safety prior to use.

Equipment must not be used unless they have a PAT test label on.

It is the users responsibility to do a visual check of the equipment.

If any defects are found (i.e. cracked casing, defect in lead etc) the equipment is not to be used, to be quarantined, safety officer informed, and a defect label attached.

Induction covers inspection of equipment before usage

Low

Med

2

Misuse of equipment

Damage to user or equipment

User, Bystander

Med

Members are inducted into the correct use of the equipment and understand associated risks.

Members found to be deliberately misusing equipment may have their use of the equipment restricted or revoked altogether.

Med

Low

3

Rosin core Solder

Flux paste

Fume Inhalation

User, Bystander

Low

A fume extractor inlet is provided on each station, that takes the fumes to a filter

Fume extractor is always powered whilst the soldering equipment has power

Do not use the soldering area if the fume extractor is inoperative

High

Low

4

Leaded Solder

Lead exposure

User

Low

Members are required to wash hands after using equipment

Food is strictly prohibited inside the soldering area

Induction covers rules

Med

Low

5

Soldering Irons

Hot Air Station

Hot Plate

Minor Burns

User

High

An enclosed cradle is provided for stowing all the handheld equipment in between uses while soldering.

Induction specifies correct usage of hotplate and soldering iron

A burn kit is available in kitchen area

Induction covers safe stoage of equipment

Med

Low

6

Spitting Solder,

Cutting Component Legs

Damange to Eyes

User

High

Goggles must be worn whilst using the station

Induction covers usage and location of goggles

Low

Low

7

Loose Hair/Clothing

Clothes/Hair catching Fire/Melting

Knocking hot equipment out of their station/workspace

User

Med

Members are required to tie hair back whilst using the station

Members are not permitted to use the soldering area in loose fitting clothing

Induction covers correct attire in the soldering area

Med

Med

9

Overcrowding

Contact with hot equipment

Knocking hot equipment out of their station/workspace

User, Bystander

Med

There is a maximum of 3 people in the soldering area

Induction covers space limits

Low

Low

10

Hot air station

Heat misdirected towards flammable material

Space

High

The handpiece is not to be set down except inside its station

The station must be positioned such that the hot air jet is not pointing towards any flammable material during use

Station detects when the handpiece is placed in its cradle and reduces temperature and blow speed

Induction covers safe usage and storage

Low

Low


Revision #3